What is AOD9604?
AOD9604 is a 16 amino acid sequence for laboratory research, and we supply it as a lyophilized powder. Researchers also handle AOD9604 as a water soluble reference peptide, so its sequence and molecular weight define it.
AOD9604 structure and sequence
The sequence is Tyr-Leu-Arg-Ile-Val-Gln-Cys-Arg-Ser-Val-Glu-Gly-Ser-Cys-Gly-Phe, molecular weight 1815.1 g/mol. Structural modification: Disulfide bond between Cys7 and Cys14.
For independent reference data, see the PubChem record for AOD9604.
Where this material appears in the literature
AOD9604 corresponds to a modified fragment of the C-terminal region of human growth hormone, and appears in preclinical receptor studies and peptide stability work. However, Inferred Labs supplies the material for in vitro laboratory investigation only. We make no claim about what it does in any living subject.
Related material in the catalog
Inferred Labs lists AOD9604 under mid chain peptides.
AOD9604 analysis and certification
Before we release any lot, an independent laboratory analyzes it. The lab uses RP-HPLC to measure purity and LC-MS to confirm identity. We then publish the certificate of analysis against the lot number, not the product page. As a result, the document you read is the document for the vial you receive. The lot number on the vial label links the two, and you can look it up in our COA library.
Purity and the certificate of analysis
We do not quote one purity figure for the whole catalog. Instead, each certificate of analysis states the measured RP-HPLC result for that lot. The certificate is therefore the record that applies to your material. Analytical figures relate only to the lot they cover. They also carry no implication of suitability for any purpose beyond laboratory research.
Research use only
Inferred Labs supplies this material for laboratory research only. We do not supply it for any use in humans or animals. It is not a drug, dietary supplement, food or cosmetic. Nothing on this page describes or implies any such use. In addition, we only sell to persons aged 21 or over. Each buyer must be a qualified researcher or buy for a research institution, laboratory or business.
| Compound |
AOD9604 |
| Also known as |
Tyr-hGH(177-191) |
| Class |
Synthetic peptide |
| Amino acids |
16 |
| Sequence |
Tyr-Leu-Arg-Ile-Val-Gln-Cys-Arg-Ser-Val-Glu-Gly-Ser-Cys-Gly-Phe |
| Modification |
Disulfide bond between Cys7 and Cys14 |
| Molecular formula |
C78H123N23O23S2 |
| Molecular weight |
1815.1 g/mol |
| CAS number |
221231-10-3 |
| Appearance |
White to off white lyophilized powder |
| Purity |
Measured per lot, stated on the certificate of analysis |
| Purity method |
RP-HPLC |
| Identity method |
LC-MS |
| Solubility |
Soluble in sterile water and aqueous buffers for analytical preparation |
| Labeled quantity |
10mg per vial |
Characterization. Values above describe the compound as supplied. The figures for the lot you receive, including measured purity, are stated on its certificate of analysis.
How this material is tested
Two separate analyses are carried out on every lot before release, and both appear on the certificate.
- RP-HPLC, for purity. Reversed phase high performance liquid chromatography separates the material by hydrophobicity. The main peak is integrated against total peak area, and that ratio is the purity figure reported on the certificate.
- LC-MS, for identity. Liquid chromatography coupled to mass spectrometry confirms that the mass of the main peak matches the expected mass for the compound, which is what distinguishes the correct sequence from a closely related one.
A complete certificate carries the compound name, the lot number, the test date, the method, the measured purity and the name of the laboratory. If any of those is missing, or the lot number on the vial does not match the certificate, contact us before using the material.
Storing AOD9604
Lyophilized material is shipped cold and should be moved into freezer storage on arrival. Store the sealed vial dry at −20°C or below, protected from light and moisture. Returned promptly to those conditions, the dry solid is the most stable form this material takes.
Preparing stock solutions
Prepare stock solutions in sterile water or an appropriate aqueous buffer at a concentration suited to your assay, expressed in mg/mL. Allow the vial to reach room temperature before opening, add solvent down the vial wall rather than directly onto the solid, and let the material dissolve without vigorous agitation. AOD9604 dissolves readily in water at the concentrations used for analytical work.
Solutions are less stable than the lyophilized solid. Prepare close to the point of use, hold at 2 to 8°C for short periods only, and aliquot before freezing so that repeated freeze and thaw cycles are avoided.
On arrival
Check that the vial is intact and sealed, that the compound name and labeled quantity match your order, and that the lot number on the label matches the certificate published for it. If anything does not match, or the packaging has clearly failed in transit, contact us before using the material. Problems visible on arrival should be reported within 7 days so that a carrier claim remains possible.
Handling and disposal
Assess the hazards of this material before handling it and use appropriate controls and protective equipment. It has not been characterized toxicologically and should be treated as potentially hazardous. Anyone handling it should be trained for the work.
Dispose of unused material, vials and packaging lawfully and in line with your institution's waste procedures.
Record keeping
Record the lot number in your notes at the point of first use, alongside the date the vial was opened and the concentration of any stock prepared. Certificates are published against the lot number rather than the product, so the lot number is the only reliable link between your results and the analytical data for the material that produced them. If a question arises about a result months later, that link is what keeps the work auditable.